6.3 sec in total
2.1 sec
4 sec
136 ms
Click here to check amazing E Technik Uni Erlangen content for Germany. Otherwise, check out these important facts you probably never knew about e-technik.uni-erlangen.de
16 Lehrstühle, International AudioLabs. Grundlagen, Spezialthemen der Elektrotechnik, Elektronik, Informationstechnik in Forschung, Lehre.
Visit e-technik.uni-erlangen.deWe analyzed E-technik.uni-erlangen.de page load time and found that the first response time was 2.1 sec and then it took 4.1 sec to load all DOM resources and completely render a web page. This is a poor result, as 65% of websites can load faster.
e-technik.uni-erlangen.de performance score
name
value
score
weighting
Value3.7 s
29/100
10%
Value10.3 s
0/100
25%
Value9.8 s
10/100
10%
Value5,190 ms
0/100
30%
Value0.341
33/100
15%
Value21.1 s
1/100
10%
2115 ms
683 ms
921 ms
923 ms
1110 ms
Our browser made a total of 41 requests to load all elements on the main page. We found that all of those requests were addressed to E-technik.uni-erlangen.de and no external sources were called. The less responsive or slowest element that took the longest time to load (2.1 sec) belongs to the original domain E-technik.uni-erlangen.de.
Page size can be reduced by 194.3 kB (40%)
485.4 kB
291.1 kB
In fact, the total size of E-technik.uni-erlangen.de main page is 485.4 kB. This result falls beyond the top 1M of websites and identifies a large and not optimized web page that may take ages to load. 25% of websites need less resources to load. Images take 238.0 kB which makes up the majority of the site volume.
Potential reduce by 10.5 kB
HTML content can be minified and compressed by a website’s server. The most efficient way is to compress content using GZIP which reduces data amount travelling through the network between server and browser. This page needs HTML code to be minified as it can gain 2.6 kB, which is 19% of the original size. It is highly recommended that content of this web page should be compressed using GZIP, as it can save up to 10.5 kB or 76% of the original size.
Potential reduce by 3.9 kB
Image size optimization can help to speed up a website loading time. The chart above shows the difference between the size before and after optimization. E Technik Uni Erlangen images are well optimized though.
Potential reduce by 69.5 kB
It’s better to minify JavaScript in order to improve website performance. The diagram shows the current total size of all JavaScript files against the prospective JavaScript size after its minification and compression. It is highly recommended that all JavaScript files should be compressed and minified as it can save up to 69.5 kB or 65% of the original size.
Potential reduce by 110.4 kB
CSS files minification is very important to reduce a web page rendering time. The faster CSS files can load, the earlier a page can be rendered. E-technik.uni-erlangen.de needs all CSS files to be minified and compressed as it can save up to 110.4 kB or 87% of the original size.
Number of requests can be reduced by 12 (30%)
40
28
The browser has sent 40 CSS, Javascripts, AJAX and image requests in order to completely render the main page of E Technik Uni Erlangen. We recommend that multiple CSS and JavaScript files should be merged into one by each type, as it can help reduce assets requests from 13 to 1 for CSS and as a result speed up the page load time.
e-technik.uni-erlangen.de
2115 ms
layout.css
683 ms
tools.css
921 ms
flexslider.css
923 ms
jquery-1.7.2.min.js
1110 ms
jquery.flexslider-min.js
923 ms
base.css
98 ms
base_ym3.css
96 ms
basemod.css
194 ms
content.css
191 ms
basemod_zusatzinfo.css
287 ms
basemod_sidebar.css
288 ms
basemod_links.css
330 ms
mediaqueries.css
332 ms
basemod_gelb.css
334 ms
print.css
379 ms
balken-komplett.gif
95 ms
header-techfak-gelb-3b.png
552 ms
logo-techfak-blau-bg.png
185 ms
breadcrumbarrow.gif
100 ms
hauptmenue-bg-gelb.png
99 ms
fau-logo-weissbg-180px.gif
100 ms
audit_fgh_z_08_rgb_7_klein.jpg
316 ms
glasfasertrommel.jpg
189 ms
richtfunk.jpg
191 ms
reinraumlabor.jpg
191 ms
zss.jpg
368 ms
reinraumhalle.jpg
283 ms
energie.jpg
284 ms
mp3.jpg
284 ms
miniskiip.jpg
466 ms
pendolino.jpg
377 ms
digital-video-broadcasting.jpg
378 ms
mikrochip.jpg
499 ms
elektrische-energie-hochspannung.jpg
460 ms
elektroauto.jpg
470 ms
touchscreen.jpg
472 ms
windkraft.jpg
553 ms
handy.jpg
557 ms
extern.gif
562 ms
web-banner-fau-eei-inf-16.gif
929 ms
e-technik.uni-erlangen.de accessibility score
e-technik.uni-erlangen.de best practices score
Trust and Safety
Impact
Issue
Does not use HTTPS
Ensure CSP is effective against XSS attacks
General
Impact
Issue
Detected JavaScript libraries
e-technik.uni-erlangen.de SEO score
Mobile Friendly
Make sure your pages are mobile friendly so users don’t have to pinch or zoom in order to read the content pages. [Learn more](https://developers.google.com/search/mobile-sites/).
Impact
Issue
Document uses legible font sizes
DE
DE
UTF-8
Language claimed in HTML meta tag should match the language actually used on the web page. Otherwise E-technik.uni-erlangen.de can be misinterpreted by Google and other search engines. Our service has detected that German is used on the page, and it matches the claimed language. Our system also found out that E-technik.uni-erlangen.de main page’s claimed encoding is utf-8. Use of this encoding format is the best practice as the main page visitors from all over the world won’t have any issues with symbol transcription.
e-technik.uni-erlangen.de
Open Graph description is not detected on the main page of E Technik Uni Erlangen. Lack of Open Graph description can be counter-productive for their social media presence, as such a description allows converting a website homepage (or other pages) into good-looking, rich and well-structured posts, when it is being shared on Facebook and other social media. For example, adding the following code snippet into HTML <head> tag will help to represent this web page correctly in social networks: