Report Summary

  • 80

    Performance

    Renders faster than
    86% of other websites

  • 88

    Accessibility

    Visual factors better than
    that of 68% of websites

  • 83

    Best Practices

    More advanced features
    available than in
    55% of websites

  • 93

    SEO

    Google-friendlier than
    83% of websites

ecoelectrical.co.uk

Eco Electrical - Sustainable Energy Advice and Design

Page Load Speed

2 sec in total

First Response

651 ms

Resources Loaded

1.3 sec

Page Rendered

93 ms

ecoelectrical.co.uk screenshot

About Website

Welcome to ecoelectrical.co.uk homepage info - get ready to check Eco Electrical best content right away, or after learning these important things about ecoelectrical.co.uk

Sustainable energy solutions in Gloucestershire and the South West - we advise, design and install and can fully project manage your build.

Visit ecoelectrical.co.uk

Key Findings

We analyzed Ecoelectrical.co.uk page load time and found that the first response time was 651 ms and then it took 1.4 sec to load all DOM resources and completely render a web page. This is quite a good result, as only 30% of websites can load faster.

Performance Metrics

ecoelectrical.co.uk performance score

80

Measured Metrics

name

value

score

weighting

FCP (First Contentful Paint)

Value3.2 s

44/100

10%

LCP (Largest Contentful Paint)

Value3.8 s

55/100

25%

SI (Speed Index)

Value4.2 s

77/100

10%

TBT (Total Blocking Time)

Value30 ms

100/100

30%

CLS (Cumulative Layout Shift)

Value0.002

100/100

15%

TTI (Time to Interactive)

Value3.7 s

90/100

10%

Network Requests Diagram

ecoelectrical.co.uk

651 ms

wp-emoji-release.min.js

181 ms

style.min.css

180 ms

bootstrap.min.css

258 ms

font-awesome.min.css

177 ms

Our browser made a total of 20 requests to load all elements on the main page. We found that 85% of them (17 requests) were addressed to the original Ecoelectrical.co.uk, 10% (2 requests) were made to Fonts.gstatic.com and 5% (1 request) were made to Fonts.googleapis.com. The less responsive or slowest element that took the longest time to load (651 ms) belongs to the original domain Ecoelectrical.co.uk.

Page Optimization Overview & Recommendations

Page size can be reduced by 155.8 kB (45%)

Content Size

343.7 kB

After Optimization

187.9 kB

In fact, the total size of Ecoelectrical.co.uk main page is 343.7 kB. This result falls beyond the top 1M of websites and identifies a large and not optimized web page that may take ages to load. 25% of websites need less resources to load. Javascripts take 190.8 kB which makes up the majority of the site volume.

HTML Optimization

-71%

Potential reduce by 11.6 kB

  • Original 16.3 kB
  • After minification 15.3 kB
  • After compression 4.7 kB

HTML content can be minified and compressed by a website’s server. The most efficient way is to compress content using GZIP which reduces data amount travelling through the network between server and browser. HTML code on this page is well minified. It is highly recommended that content of this web page should be compressed using GZIP, as it can save up to 11.6 kB or 71% of the original size.

Image Optimization

-6%

Potential reduce by 4.7 kB

  • Original 84.8 kB
  • After minification 80.1 kB

Image size optimization can help to speed up a website loading time. The chart above shows the difference between the size before and after optimization. Eco Electrical images are well optimized though.

JavaScript Optimization

-67%

Potential reduce by 128.5 kB

  • Original 190.8 kB
  • After minification 188.3 kB
  • After compression 62.3 kB

It’s better to minify JavaScript in order to improve website performance. The diagram shows the current total size of all JavaScript files against the prospective JavaScript size after its minification and compression. It is highly recommended that all JavaScript files should be compressed and minified as it can save up to 128.5 kB or 67% of the original size.

CSS Optimization

-21%

Potential reduce by 11.0 kB

  • Original 51.8 kB
  • After minification 51.8 kB
  • After compression 40.8 kB

CSS files minification is very important to reduce a web page rendering time. The faster CSS files can load, the earlier a page can be rendered. Ecoelectrical.co.uk needs all CSS files to be minified and compressed as it can save up to 11.0 kB or 21% of the original size.

Requests Breakdown

Number of requests can be reduced by 13 (68%)

Requests Now

19

After Optimization

6

The browser has sent 19 CSS, Javascripts, AJAX and image requests in order to completely render the main page of Eco Electrical. We recommend that multiple CSS and JavaScript files should be merged into one by each type, as it can help reduce assets requests from 9 to 1 for JavaScripts and from 6 to 1 for CSS and as a result speed up the page load time.

Accessibility Review

ecoelectrical.co.uk accessibility score

88

Accessibility Issues

Names and labels

These are opportunities to improve the semantics of the controls in your application. This may enhance the experience for users of assistive technology, like a screen reader.

Impact

Issue

High

Image elements do not have [alt] attributes

Best Practices

ecoelectrical.co.uk best practices score

83

Areas of Improvement

Trust and Safety

Impact

Issue

High

Does not use HTTPS

High

Includes front-end JavaScript libraries with known security vulnerabilities

Low

Ensure CSP is effective against XSS attacks

General

Impact

Issue

Low

Detected JavaScript libraries

SEO Factors

ecoelectrical.co.uk SEO score

93

Search Engine Optimization Advices

Content Best Practices

Format your HTML in a way that enables crawlers to better understand your app’s content.

Impact

Issue

High

Image elements do not have [alt] attributes

Mobile Friendly

Make sure your pages are mobile friendly so users don’t have to pinch or zoom in order to read the content pages. [Learn more](https://developers.google.com/search/mobile-sites/).

Impact

Issue

High

Document uses legible font sizes

Language and Encoding

  • Language Detected

    EN

  • Language Claimed

    EN

  • Encoding

    UTF-8

Language claimed in HTML meta tag should match the language actually used on the web page. Otherwise Ecoelectrical.co.uk can be misinterpreted by Google and other search engines. Our service has detected that English is used on the page, and it matches the claimed language. Our system also found out that Ecoelectrical.co.uk main page’s claimed encoding is utf-8. Use of this encoding format is the best practice as the main page visitors from all over the world won’t have any issues with symbol transcription.

Social Sharing Optimization

Open Graph description is not detected on the main page of Eco Electrical. Lack of Open Graph description can be counter-productive for their social media presence, as such a description allows converting a website homepage (or other pages) into good-looking, rich and well-structured posts, when it is being shared on Facebook and other social media. For example, adding the following code snippet into HTML <head> tag will help to represent this web page correctly in social networks: