2.8 sec in total
106 ms
1.7 sec
1 sec
Welcome to troyelectric.com homepage info - get ready to check Troy Electric best content right away, or after learning these important things about troyelectric.com
Since 1973, Troy Electric is Victoria's most trusted source for quality repair services for marine, commercial, and industrial electro-mechanical needs.
Visit troyelectric.comWe analyzed Troyelectric.com page load time and found that the first response time was 106 ms and then it took 2.7 sec to load all DOM resources and completely render a web page. This is a poor result, as 50% of websites can load faster.
troyelectric.com performance score
name
value
score
weighting
Value3.3 s
40/100
10%
Value6.2 s
11/100
25%
Value4.4 s
74/100
10%
Value600 ms
49/100
30%
Value0.298
40/100
15%
Value10.0 s
26/100
10%
106 ms
176 ms
27 ms
261 ms
27 ms
Our browser made a total of 49 requests to load all elements on the main page. We found that 65% of them (32 requests) were addressed to the original Troyelectric.com, 24% (12 requests) were made to Fonts.gstatic.com and 4% (2 requests) were made to Googletagmanager.com. The less responsive or slowest element that took the longest time to load (472 ms) belongs to the original domain Troyelectric.com.
Page size can be reduced by 118.7 kB (5%)
2.2 MB
2.1 MB
In fact, the total size of Troyelectric.com main page is 2.2 MB. This result falls beyond the top 1M of websites and identifies a large and not optimized web page that may take ages to load. 70% of websites need less resources to load. Images take 2.0 MB which makes up the majority of the site volume.
Potential reduce by 76.2 kB
HTML content can be minified and compressed by a website’s server. The most efficient way is to compress content using GZIP which reduces data amount travelling through the network between server and browser. HTML code on this page is well minified. It is highly recommended that content of this web page should be compressed using GZIP, as it can save up to 76.2 kB or 85% of the original size.
Potential reduce by 10.4 kB
Image size optimization can help to speed up a website loading time. The chart above shows the difference between the size before and after optimization. Troy Electric images are well optimized though.
Potential reduce by 32.0 kB
It’s better to minify JavaScript in order to improve website performance. The diagram shows the current total size of all JavaScript files against the prospective JavaScript size after its minification and compression. It is highly recommended that all JavaScript files should be compressed and minified as it can save up to 32.0 kB or 56% of the original size.
Number of requests can be reduced by 11 (34%)
32
21
The browser has sent 32 CSS, Javascripts, AJAX and image requests in order to completely render the main page of Troy Electric. We recommend that multiple CSS and JavaScript files should be merged into one by each type, as it can help reduce assets requests from 9 to 1 for JavaScripts and from 4 to 1 for CSS and as a result speed up the page load time.
troyelectric.com
106 ms
www.troyelectric.com
176 ms
wp-emoji-release.min.js
27 ms
37fe4.css
261 ms
css
27 ms
0cff0.css
294 ms
df983.js
304 ms
fa2f4.js
293 ms
f32d4.css
244 ms
75743.js
472 ms
af37c.js
472 ms
e1a82.js
472 ms
gtm.js
263 ms
6-Welding-Equipment-Repair-1024x678-2.png
147 ms
home_about_img.png
340 ms
troy_logo_500-300x69.png
128 ms
troy-vfd-1-768x512.jpg
213 ms
6-Welding-Equipment-Repair-1024x678-2.png
157 ms
6-Welding-Equipment-Repair-1024x678-1.png
127 ms
6-Welding-Equipment-Repair-1024x678-3.png
163 ms
6-Welding-Equipment-Repair-1024x678-11-1.png
127 ms
industrial-services.png
209 ms
6-Welding-Equipment-Repair-1024x678-1-1.png
210 ms
navy_work.png
212 ms
before_after_vfd_fan_cleaning.png
303 ms
before_after_vfd_circuit_board.png
337 ms
before_after_uvic.png
260 ms
Grundfos_Authorized-Service-Partner_Panel_US_SCREEN.png
210 ms
bbb_rating.png
256 ms
troy-electric-new-rating-01.png
256 ms
yellow_pages_rating.png
257 ms
KFOmCnqEu92Fr1Mu4mxP.ttf
45 ms
KFOlCnqEu92Fr1MmEU9fBBc9.ttf
63 ms
KFOlCnqEu92Fr1MmSU5fBBc9.ttf
61 ms
KFOkCnqEu92Fr1MmgVxIIzc.ttf
64 ms
KFOlCnqEu92Fr1MmWUlfBBc9.ttf
66 ms
KFOlCnqEu92Fr1MmYUtfBBc9.ttf
66 ms
fa-solid-900.woff
213 ms
KFOkCnqEu92Fr1Mu51xIIzc.ttf
64 ms
KFOjCnqEu92Fr1Mu51S7ACc6CsE.ttf
67 ms
KFOjCnqEu92Fr1Mu51TjASc6CsE.ttf
67 ms
KFOiCnqEu92Fr1Mu51QrEzAdKg.ttf
69 ms
KFOjCnqEu92Fr1Mu51TzBic6CsE.ttf
69 ms
KFOjCnqEu92Fr1Mu51TLBCc6CsE.ttf
68 ms
eicons.woff
211 ms
fa-brands-400.woff
166 ms
js
81 ms
analytics.js
24 ms
collect
43 ms
troyelectric.com accessibility score
ARIA
These are opportunities to improve the usage of ARIA in your application which may enhance the experience for users of assistive technology, like a screen reader.
Impact
Issue
[aria-hidden="true"] elements contain focusable descendents
Contrast
These are opportunities to improve the legibility of your content.
Impact
Issue
Background and foreground colors do not have a sufficient contrast ratio.
Navigation
These are opportunities to improve keyboard navigation in your application.
Impact
Issue
Heading elements are not in a sequentially-descending order
Names and labels
These are opportunities to improve the semantics of the controls in your application. This may enhance the experience for users of assistive technology, like a screen reader.
Impact
Issue
Links do not have a discernible name
troyelectric.com best practices score
Trust and Safety
Impact
Issue
Does not use HTTPS
Includes front-end JavaScript libraries with known security vulnerabilities
Ensure CSP is effective against XSS attacks
General
Impact
Issue
Detected JavaScript libraries
troyelectric.com SEO score
Mobile Friendly
Make sure your pages are mobile friendly so users don’t have to pinch or zoom in order to read the content pages. [Learn more](https://developers.google.com/search/mobile-sites/).
Impact
Issue
Document uses legible font sizes
Tap targets are not sized appropriately
EN
EN
UTF-8
Language claimed in HTML meta tag should match the language actually used on the web page. Otherwise Troyelectric.com can be misinterpreted by Google and other search engines. Our service has detected that English is used on the page, and it matches the claimed language. Our system also found out that Troyelectric.com main page’s claimed encoding is utf-8. Use of this encoding format is the best practice as the main page visitors from all over the world won’t have any issues with symbol transcription.
troyelectric.com
Open Graph data is detected on the main page of Troy Electric. This is the best way to make the web page social media friendly. Here is how it looks like on Facebook: